Service

ICU Setup

Complete turnkey ICU infrastructure — layout, modular finishes, HVAC, bed head panels, gas terminals, and equipment integration — built to NABH and ISCCM standards across India.

What a Turnkey ICU Setup Includes

An intensive care unit is the most infrastructure-dense space in a hospital. A single Level III bed carries more services per square metre than an operation theatre: oxygen, medical air, vacuum, essential and UPS power, data, nurse call, and a ceiling structure capable of carrying a loaded pendant — all converging on a two-metre bed footprint that a resuscitation team must be able to surround from every side.

That density is why fragmented procurement fails so often. The HVAC contractor sizes the AHU before anyone confirms the ventilator count. The gas contractor routes copper where the pendant boom needs to swing. The panel supplier delivers bed head units with the wrong outlet configuration for the monitors that arrive three months later. Each vendor is individually compliant and the unit as a whole does not work.

A turnkey ICU setup collapses those interfaces into one contract. As an ICU setup company in India, RayMedico Projects takes responsibility for the whole envelope: capacity planning and layout, civil interface and modular finishes, HVAC and filtration, medical gas pipeline and terminal units, bed head panels and pendants, nurse call and central monitoring, isolation rooms, electrical and IT backbone, equipment integration, validation, and the documentation pack your NABH assessor will ask for.

The demand for this is not evenly distributed. Critical care capacity in India remains concentrated in metro tier-1 hospitals, while tier-2 and tier-3 districts absorb a disproportionate share of trauma, sepsis, and obstetric emergencies with commonly cited ICU bed availability in the low single digits per 100,000 population. The gap is being closed one 8-to-20-bed unit at a time, usually by hospitals that do not have an in-house projects department and cannot afford to manage nine vendors.

ICU Levels Explained: Level I, II and III

Almost every costing mistake in critical care unit setup starts with an unstated assumption about level of care. “ICU” is not a specification. The level is.

Level I — observation and stabilisation. Continuous monitoring, oxygen therapy, non-invasive ventilation, and short-term invasive ventilation pending transfer. Nursing runs at roughly 1:2 or 1:3. Infrastructure demands are real but modest: reliable oxygen and vacuum at every bed, essential power, monitoring at each bay, and a nurse station with direct sightlines. Typical of secondary hospitals and nursing homes that stabilise and refer.

Level II — sustained organ support. Prolonged mechanical ventilation, vasoactive support, and management of two or more failing organ systems, with resident medical cover round the clock. Nursing tightens to 1:1 or 1:2. Infrastructure rises accordingly: higher oxygen flow capacity and manifold redundancy, UPS-backed bedside outlets, pendants rather than bare bed head panels at ventilated bays, at least one isolation room, and HVAC with terminal filtration.

Level III — full multi-organ support. Everything above plus renal replacement therapy, advanced haemodynamic monitoring, and in cardiac units, mechanical circulatory support. Nursing is 1:1. This is where infrastructure decisions become non-negotiable: N+1 gas supply, isolated power supply panels at bedside, generous ceiling load provision, dedicated isolation capability, and the shortest possible transfer path to OT, cath lab, and imaging.

AttributeLevel ILevel IILevel III
Nurse-to-bed ratio1:2 – 1:31:1 – 1:21:1
Ventilation capabilityShort-term / NIVSustained invasiveSustained + advanced modes
Oxygen outlets per bed22 – 33 – 4
Bedside supplyBed head panelPanel or pendantPendant / bridge
Isolation roomsOptionalMinimum 11 per 10 beds
Design ACH6 – 1010 – 1212 – 15
Indicative cost per bed₹8-12 lakh₹12-18 lakh₹18-25 lakh

Get the level right at planning stage and the budget holds. Get it wrong and you either overspend on infrastructure the clinical team will never use, or you build a unit that cannot be upgraded without opening the ceiling again.

Types of ICU We Build

Medical ICU (MICU). General adult critical care — sepsis, respiratory failure, poisoning, metabolic emergencies. High isolation demand because admissions are undifferentiated on arrival. Standard configuration is open bays with at least one negative-pressure room.

Surgical ICU (SICU). Post-operative critical care, sited for the shortest possible route from the operation theatre complex. Needs generous pendant provision, wide door and corridor clearances for bed transfers with attached equipment, and coordinated gas capacity with the OT block.

Cardiac ICU / CCU. Continuous telemetry, defibrillators at every bay, provision for temporary pacing and intra-aortic balloon pump, and immediate proximity to the cath lab. Electrical design here is the differentiator — clean supply, isolated power, and monitoring network reliability matter more than in a general unit.

NICU. Neonatal intensive care runs warmer (24-28°C), quieter, and darker than adult critical care. National Neonatology Forum guidance points to roughly 100-120 sq ft per Level III cot with at least 1.2 m between incubators. Every cot needs multiple oxygen, medical air, and vacuum outlets for blended gas delivery, dimmable indirect lighting, and space for warmers, phototherapy units, and parents. NICU setup is one of the most exacting builds in a hospital because it combines high service density with the strictest environmental control.

PICU. Paediatric intensive care sits between the two — adult-scale equipment loads with paediatric-scale beds, plus space at the bedside for an accompanying parent and provision for age-appropriate consumable sizing.

Trauma ICU. Designed around throughput: direct access from casualty, wider bays for spinal boards and traction, portable imaging clearance around every bed, and higher-than-normal ceiling load allowance for suspended traction and transfer systems.

Isolation / negative-pressure ICU. Either dedicated rooms within a general unit or a full unit designed as a negative-pressure suite with anteroom-controlled entry, dedicated exhaust risers, and HEPA-filtered discharge. Post-2020 this has moved from optional to expected in most tender specifications.

HDU. The step-down unit — high dependency care at roughly 1:2 or 1:3 nursing, without full ventilator provision at every bed. Typically ₹5-8 lakh per bed. A properly sized HDU is the cheapest way to protect expensive ICU capacity from being occupied by patients who no longer need it.

ICU Setup Cost Per Bed in India

ICU setup cost per bed in India ranges from ₹8 lakh to ₹25 lakh, depending on level of care. Level I units run ₹8-12 lakh per bed, Level II units ₹12-18 lakh, and Level III units ₹18-25 lakh. These figures cover infrastructure, HVAC, medical gas, bedside services, and clinical equipment inside an existing civil shell.

Here is the same money broken down by cost head, per bed:

Cost headLevel ILevel IILevel III
Civil interface, modular finishes, partitions₹1.2 – 1.8 L₹1.8 – 2.6 L₹2.5 – 3.5 L
HVAC — AHU, ducting, filtration, controls₹1.5 – 2.2 L₹2.2 – 3.2 L₹3.0 – 4.5 L
Medical gas pipeline and terminal units₹0.5 – 0.8 L₹0.8 – 1.2 L₹1.2 – 1.8 L
Bed head panel / ICU pendant₹0.4 – 0.7 L₹0.7 – 1.5 L₹1.5 – 3.0 L
Electrical, UPS, IPS, IT, nurse call₹0.8 – 1.2 L₹1.2 – 1.8 L₹1.8 – 2.7 L
Clinical equipment — monitor, ventilator, pumps, bed₹3.0 – 4.5 L₹4.5 – 6.5 L₹7.0 – 8.0 L
Central monitoring, furniture, commissioning₹0.6 – 0.8 L₹0.8 – 1.2 L₹1.0 – 1.5 L
Total per bed₹8 – 12 L₹12 – 18 L₹18 – 25 L

Scaled to whole projects:

Unit sizeLevel ILevel IILevel III
6 beds₹48 L – ₹72 L₹72 L – ₹1.08 Cr₹1.08 Cr – ₹1.5 Cr
10 beds₹80 L – ₹1.2 Cr₹1.2 Cr – ₹1.8 Cr₹1.8 Cr – ₹2.5 Cr
20 beds₹1.6 Cr – ₹2.4 Cr₹2.4 Cr – ₹3.6 Cr₹3.6 Cr – ₹5.0 Cr

Three things move these numbers more than anything else.

Equipment share. Clinical equipment is 35-40 percent of the per-bed figure, and it is the most elastic line in the budget. The gap between a mid-tier and a premium ventilator is often ₹4-6 lakh per unit. Infrastructure, by contrast, varies within a much narrower band — which is precisely why cutting infrastructure to fund equipment is a false economy. You can replace a monitor in a week. You cannot re-duct a live ICU.

Scale. Per-bed cost drops roughly 8-12 percent above twelve beds because the AHU, gas manifold, central monitoring station, and utility rooms are shared across more beds. A 6-bed unit carries the same fixed plant as a 12-bed unit.

Retrofit versus greenfield. Converting an existing ward typically costs 15-25 percent less than building on a bare floor, provided the slab carries the AHU and pendant loads and the floor-to-soffit height allows ducting. Where it does not, the saving evaporates.

Excluded from all figures above: the base civil shell and structure, HT power and DG sets, medical gas plant room and PSA oxygen generation, lifts and facade, consumables, GST, and annual maintenance. We quote these separately and explicitly so the comparison against other bids is honest.

ICU Design & Layout

Layout is where a unit is won or lost, and it is the cheapest thing to get right — it costs nothing extra at drawing stage and is close to unfixable afterwards.

Space per bed. ISCCM planning guidance places an open-bay bed at 125-150 sq ft of clinical area and a single or isolation room at 150-200 sq ft plus anteroom. Support space roughly doubles that: budget 250-300 sq ft gross per bed once nurse station, clean and dirty utility, store, duty rooms, pantry, and circulation are counted. Units planned at bed-area-only invariably end up with equipment stored in corridors.

Bed spacing. Minimum 2.4-2.5 m centre to centre, with at least 1 m clear at the foot and on one side. The test is practical, not dimensional: can a portable X-ray unit be positioned, and can six people work a cardiac arrest without moving furniture?

Nurse station sightlines. Direct line of sight from the nurse station to every bed head, with no more than about 12 m from station to the furthest bed. Glazed cubicle fronts with integral blinds resolve the tension between observation and privacy. Where sightlines are geometrically impossible — an L-shaped floor plate, for instance — the answer is a second sub-station, not a camera.

Clean and dirty zoning. One-directional flow. Clean utility, linen, and sterile stores enter from the clean side; the dirty utility, sluice, and waste hold exit on the opposite side with no crossing of the clean corridor. Separate the staff entry, patient transfer, and visitor viewing routes. NABH assessors trace these flows on the drawing before they walk the floor.

Isolation room placement. At the entry end of the unit, so an infectious admission never travels past open bays. Each isolation room gets an anteroom, an independent exhaust path, and a permanently visible differential pressure indicator outside the door.

Support spaces. Doctors’ duty room, nurses’ station and rest area, equipment store sized for what the unit actually owns, medication preparation area, and a family counselling room. The counselling room is the one most often deleted at value-engineering stage and the one most often retrofitted within a year.

HVAC, Air Changes and Infection Control

ICU ventilation carries three jobs simultaneously: dilute and remove airborne contaminant, hold temperature and humidity inside a therapeutic band, and control the direction of air movement between spaces.

Air change rates. ASHRAE 170 sets 6 total ACH minimum for critical care with 2 outdoor air changes. That is a floor, not a target. We design general ICU bays at 10-15 ACH because Indian ambient particulate loading is well above the assumptions behind the standard, and because the marginal cost of the extra capacity at design stage is a fraction of the cost of adding it later.

Filtration. Multi-stage — a MERV 7 or equivalent pre-filter, MERV 13/14 fine filtration at the AHU, and HEPA H13/H14 terminal filtration at supply grilles serving isolation rooms and immunocompromised bays. Filter housings must be gasket-sealed and accessible for scan testing without entering the clinical space.

Temperature and humidity. 21-24°C for adult ICU, 24-28°C for NICU, with relative humidity held between 30 and 60 percent. The upper humidity limit is the one that fails in Indian coastal and monsoon conditions; specify dehumidification capacity explicitly rather than assuming the cooling coil will handle it.

Pressure regimes. General ICU bays are typically neutral to slightly positive relative to the corridor. Protective environment rooms for immunocompromised patients run positive at about +2.5 Pa with HEPA supply. Airborne infection isolation rooms run negative at about -2.5 Pa with a minimum 12 ACH and direct exhaust to atmosphere, discharged clear of any air intake. Each pressure-critical room gets a differential pressure monitor with local alarm.

Envelope integrity. Pressure regimes only hold if the room is sealed. That means sealed cable and pipe penetrations, self-closing doors with appropriate undercuts, continuous ceiling systems rather than lay-in tiles in isolation rooms, and coved skirting at every floor-wall junction. A well-specified AHU feeding a leaky room achieves nothing measurable.

Equipment Integration

The distinction that matters in turnkey ICU setup is between equipment supply and equipment integration. Supply is a purchase order. Integration is making sure the infrastructure was designed for what arrives.

Monitoring. Multipara bedside monitors — ECG, SpO2, NIBP, invasive pressure, temperature, capnography as required by level — networked to a central station. Integration work is upstream: network drop position in the bed head panel, PoE or dedicated supply, VLAN segregation from the hospital’s general network, and an interface path to the HIS or EMR so vitals do not have to be transcribed by hand.

Ventilators. Each ventilated bay needs oxygen and medical air at correct pressure and flow, a UPS-backed outlet on a dedicated circuit, and a pendant or panel mount rated for the ventilator’s weight and swing. Manifold and plant capacity must be sized for simultaneous peak demand across all ventilated beds, not average consumption.

Infusion. Four to twelve channels per Level III bed across syringe and volumetric pumps. This drives socket count in the bed head panel and pole or rail provision on the pendant more than any other single factor, and it is routinely under-specified.

Central monitoring station. Positioned at the nurse station with sightlines maintained, sized for the eventual bed count, and configured with alarm escalation logic. An alarm system nobody can distinguish from background noise is a patient safety problem, not just an annoyance.

Beds and ancillary. ICU beds with CPR release, X-ray translucent platforms, and lateral tilt; defibrillators, ABG analysers, dialysis provision for Level III, warming devices, and crash carts. Each has a power, gas, drainage, or floor-space implication that belongs on the services drawing.

Because RayMedico Projects builds the infrastructure and coordinates the equipment, these interfaces are resolved on paper months before delivery — rather than discovered on installation day.

Validation, Commissioning & NABH-Ready Handover

A unit is not complete when it looks finished. It is complete when it is demonstrably within specification and you hold the evidence.

Our validation and commissioning protocol covers air change rate measurement per bay, particle count testing for isolation and protective rooms, room-to-room differential pressure verification, temperature and humidity profiling across the unit, HEPA filter integrity and installed leak testing, medical gas pressure, flow, purity, and cross-connection testing with terminal unit identification, alarm and nurse call function testing at every point, electrical earthing, isolated power supply, and UPS changeover tests, illumination level measurement, and equipment commissioning with calibration certificates.

Handover documentation includes as-built drawings for architecture, HVAC, gas, and electrical services, the full validation and test report set, equipment manuals with warranty and calibration certificates, gas pipeline certification and line diagrams, a preventive maintenance schedule, and operator training records for clinical and biomedical staff.

That packet is assembled to go straight into a NABH file. Hospitals that skip formal commissioning almost always pay for it twice — once during the accreditation cycle when evidence has to be reconstructed retrospectively, and again when an undetected out-of-spec condition surfaces clinically.

Why RayMedico Projects

Single accountable partner. Layout, finishes, HVAC, gas, electricals, IT, and equipment under one contract and one project manager. When the pendant boom and the duct run conflict, we resolve it. You do not chair the meeting.

Level-appropriate engineering. We start by establishing your level of care, case mix, and growth trajectory, then engineer to it. No Level III specification sold to a hospital that needs Level II. No Level I infrastructure quietly installed under a Level III equipment list.

Compliance built in. NABH, ISCCM, ASHRAE 170, ISO 14644, and NBC 2016 requirements are design inputs from the first sketch, not corrections applied after an assessor’s visit. Every unit is engineered to be audit-ready at handover.

Designed for expansion. ICUs grow. AHU capacity, gas manifold sizing, electrical risers, and network backbone are specified for your eventual bed count so the next phase is a fit-out, not a rebuild of the services spine.

Ecosystem support. Beyond the build, hospitals equip through RayMedico Marketplace and maintain through our AMC programme, keeping validation current and the unit in specification year after year.

Planning a new critical care unit, converting a ward, or expanding an existing ICU? Talk to our engineering team for a level-of-care assessment and a line-item budget.

Components & Features

What's Included

Every component engineered to work as a unified system.

🛏️

ICU Bed Head Panels

Horizontal or vertical bed head units integrating gas outlets, power sockets, data ports, examination lighting, and nurse call in one serviceable channel.

🏗️

ICU Pendants & Bridge Systems

Ceiling-mounted single, double, and bridge pendants that lift ventilator, monitor, and infusion loads off the floor for 360-degree bed access.

❄️

HVAC, HEPA & Isolation Rooms

Dedicated AHUs with multi-stage filtration, 21-24°C control, humidity limits, and negative-pressure airborne infection isolation rooms with anterooms.

📟

Nurse Call & Central Monitoring

Bedside and toilet call points, corridor annunciators, and a networked central station giving one nurse continuous visibility of every bed.

🪟

Modular Partitions & Glass Fronts

Antibacterial modular partitions with glazed fronts, integral blinds, and sliding or breakaway doors — sightlines for staff, privacy on demand.

🫁

Medical Gas Terminal Units

Oxygen, medical air, vacuum, and AGSS terminals per bed, pressure-tested and NFPA 99 / HTM 02-01 compatible, fed from a redundant manifold or PSA plant.

Built to These Standards

Our Process

Our Process

A proven five-phase approach for every project.

01

Capacity Planning & Design

Bed count optimization based on hospital size, specialty mix, case-severity profile, and growth projections — including HDU and isolation bed ratios.

02

Layout & Engineering

ICU layout following ISCCM and NABH guidelines, with clean and dirty utility zoning, nurse station sightlines, and coordinated HVAC, gas, and electrical services drawings.

03

Infrastructure Build

Modular partitions, bed head units, pendants, nurse call, isolation rooms, seamless flooring, gas pipeline, essential-load electricals, and HVAC integration.

04

Equipment Integration

Coordinated installation of multipara monitors, ventilators, infusion systems, ICU beds, and the central monitoring station — with load, mounting, and network interfaces pre-planned.

05

Validation & Handover

Air change and particle count testing, pressure differential validation, gas purity and pressure certification, equipment commissioning, staff training, and NABH-ready documentation.

Full Specification

Complete Component List

ICU bed head panels (horizontal and vertical, medical-grade extrusion)
Medical gas terminal units (oxygen, medical air, vacuum, AGSS)
Ceiling-mounted ICU pendants and bridge systems
Nurse call system with bedside, toilet pull-cord, and corridor annunciators
Central monitoring station with networked multipara monitors
Modular ICU partitions with glazed fronts and integral blinds
Negative-pressure isolation rooms with anteroom and pressure monitor
Dedicated AHU with multi-stage and HEPA terminal filtration
Pressure relief dampers and room differential pressure indicators
Seamless antibacterial vinyl or epoxy flooring with coved skirting
Washable wall cladding and hermetic or breakaway ICU doors
Clean utility, dirty utility, and sluice room fit-out
UPS, isolated power supply panels, and essential-load distribution boards
Structured cabling, HIS/EMR network points, and CCTV
Scrub stations, hand hygiene points, and PPE donning/doffing zones
Overhead IV tracks, equipment rails, and ceiling-suspended supply columns
FAQ

Frequently Asked Questions

Common questions about icu setup.

What does a turnkey ICU setup include?

A complete turnkey ICU setup includes architectural design and layout, civil work and modular finishes, HVAC system with HEPA filtration, bed head units with gas terminals, nurse call system, ICU pendants, isolation room construction, electrical and IT infrastructure, equipment supply and integration, validation testing, and NABH-ready documentation. Turnkey means one contract and one project manager across all of it, so the HVAC designer, the gas contractor, the panel manufacturer, and the equipment supplier are coordinated by a single accountable party rather than by your projects team.

What is the cost of ICU setup per bed in India?

ICU setup costs in India typically range from ₹10-25 lakh per bed depending on ICU level, equipment selection, and infrastructure scope. Level III ICU (highest acuity) with full equipment ranges ₹18-25 lakh per bed; Level II ranges ₹12-18 lakh; Level I starts around ₹8-12 lakh per bed. These figures include infrastructure, HVAC, and equipment but exclude consumables. They also exclude the base civil shell, HT power and DG sets, GST, and annual maintenance. Per-bed cost falls roughly 8-12 percent above twelve beds, because the AHU, gas manifold, and central monitoring station are shared across more beds.

What is the difference between Level I, Level II and Level III ICU?

The levels describe acuity and the infrastructure each demands. A Level I unit handles monitoring, short-term ventilation, and stabilisation before transfer — it needs reliable oxygen, suction, monitoring, and a nurse-to-bed ratio near 1:2 or 1:3. A Level II unit provides sustained mechanical ventilation and multi-organ support, requiring higher gas flow capacity, resident medical cover, and 1:1 or 1:2 nursing. A Level III unit delivers full multi-organ support including renal replacement and advanced haemodynamic monitoring, with 1:1 nursing, isolation capability, and the most demanding electrical, gas, and HVAC redundancy.

How much space is required per ICU bed?

ISCCM planning guidance places an open-bay ICU bed at roughly 125-150 sq ft of clinical floor area, and a single or isolation room at 150-200 sq ft plus an anteroom. Once you add the nurse station, clean and dirty utility, store, doctor and nurse duty rooms, pantry, and circulation, the gross area required is about 250-300 sq ft per bed. Bed centre-to-centre spacing should be at least 2.4-2.5 m, with a minimum 1 m clear at the foot and one side to allow a portable X-ray unit and a full resuscitation team around the bed.

How many air changes per hour does an ICU need?

ASHRAE 170 sets a floor of 6 total air changes per hour for critical care spaces, with at least 2 outdoor air changes, MERV 7 pre-filtration and MERV 14 final filtration, 21-24°C design temperature, and relative humidity held between 30 and 60 percent. In Indian practice we design general ICU bays at 10-15 ACH with HEPA terminal filtration, because ambient particulate loading is far higher than the standard assumes. Airborne infection isolation rooms move to 12 ACH minimum with negative pressure and direct exhaust to atmosphere.

How long does it take to set up an ICU?

A 10-bed ICU inside a completed civil shell typically takes 75-110 days from order confirmation. That divides into design and client approval of layout, services, and equipment schedules (15-20 days), manufacturing of bed head panels, pendants, partitions, and AHU (30-45 days), site installation of finishes, HVAC, gas pipeline, and electricals (25-35 days), and validation, commissioning, and staff training (7-10 days). Greenfield floors that need civil, structural, or facade work first will run longer. Retrofits inside a live hospital are phased in bays to keep part of the unit operational.

What is a negative-pressure isolation room and when is it needed?

A negative-pressure or airborne infection isolation room holds the patient space at roughly 2.5 Pa below the adjoining corridor, so air always flows inward and contaminated air is exhausted directly to atmosphere rather than recirculated. It needs a sealed envelope, an anteroom for PPE donning and doffing, a minimum 12 air changes per hour, a permanent differential pressure monitor with alarm, and self-closing doors. It is required for suspected or confirmed airborne transmissible disease — tuberculosis, measles, and pandemic respiratory illness — and NABH assessors look for at least one such room in any ICU accepting undifferentiated admissions.

What are the NABH requirements for an ICU?

NABH assesses ICU infrastructure on defined bed spacing and unobstructed access, hand hygiene facilities within reach of every bed, at least one isolation bed, uninterrupted medical gas and vacuum with alarmed manifolds, backed-up essential power reaching every bedside outlet, controlled temperature and humidity with documented air change validation, seamless cleanable surfaces, clear separation of clean and dirty utility flows, functioning nurse call, and a written equipment maintenance and calibration record. The practical requirement is evidence: assessors want commissioning reports, validation certificates, and calibration logs, not just correct construction.

How many ICU beds should a hospital plan for?

A common planning basis in India is 5-10 percent of total inpatient beds for intensive care, rising to 10-15 percent in tertiary, trauma, cardiac, and oncology centres where case severity is higher. A 100-bed secondary hospital usually lands on 8-12 critical care beds, often split into a general ICU and a step-down HDU. Plan at least one isolation bed per 10 ICU beds, size the AHU and gas manifold for the eventual bed count rather than day-one occupancy, and leave a knock-out wall or spare bay so expansion does not mean rebuilding the services backbone.

What is required for a NICU setup?

NICU infrastructure differs from adult critical care in several specific ways. Ambient temperature is held at 24-28°C rather than 21-24°C, humidity is controlled tightly, and lighting must be dimmable with individually switched examination lights to protect neonatal circadian development. National Neonatology Forum guidance points to about 100-120 sq ft per Level III cot with at least 1.2 m between incubators, and around 50 sq ft per cot in Level II special newborn care. Each cot needs multiple oxygen, air, and vacuum outlets for blended gas delivery, plus dedicated space for phototherapy, warmers, and parent access.

Can an existing ward be converted into an ICU?

Yes, and ward-to-ICU conversion is a large share of critical care expansion in tier-2 and tier-3 hospitals. The feasibility test is structural and mechanical, not cosmetic: floor-to-soffit height must allow ducting and pendant loads, the slab must carry the AHU and ceiling-mounted equipment, and the electrical riser must support the additional essential and UPS load. Conversions typically cost 15-25 percent less than a new-build floor because the shell exists, but they demand careful phasing, dust and noise containment, and temporary services so the adjacent wards continue functioning throughout.

Do you provide AMC and post-handover support for ICU infrastructure?

Yes. Annual maintenance covers the elements that quietly drift out of specification after handover — AHU servicing and filter replacement, re-validation of air change rates and room pressure differentials, medical gas pressure and purity testing, alarm and nurse call function checks, bed head panel and pendant inspection, and calibration coordination for monitoring equipment. Infrastructure AMC is generally 6-10 percent of infrastructure capital cost per year. We recommend re-validation at least annually, and always after any HVAC modification, filter change, or partition alteration inside the unit.
Where We Build

ICU Setup across India

City-specific guidance on cost, logistics, and local compliance for icu setup projects.

Ready to discuss your ICU Setup project?

Get a detailed quote, project timeline, and feasibility assessment from our team within 4 business hours.