Medical Gas Pipeline System

HTM 02-01, NFPA 99 and ISO 7396-1 compliant medical gas pipeline systems — oxygen, nitrous oxide, medical air, vacuum, AGSS and CO2 — designed, installed and certified for Indian hospitals.

What is a Medical Gas Pipeline System

A medical gas pipeline system (MGPS) is the centralised network that carries oxygen, nitrous oxide, medical air, surgical air, vacuum, AGSS and CO2 from bulk sources in the plant room to gas-specific terminal units at every point of clinical use — bedsides, operating theatres, ICUs, labour rooms and emergency departments.

It removes the labour and hazard of moving cylinders around a working hospital, guarantees a continuous pressure-regulated supply to ventilated patients, and makes gas consumption measurable, alarmed and auditable. Engineering-wise it is a life-support installation: a cross-connected outlet, a contaminated pipe run or a failed changeover manifold has clinical consequences within seconds. That is why the discipline around it — degreased copper, nitrogen-purged brazing, non-interchangeable terminals, permit-to-work systems, three-source redundancy — is closer to aviation practice than to building services.

India’s relationship with medical gas infrastructure changed permanently after 2020. The oxygen crisis exposed hospitals with pipelines sized for pre-COVID occupancy, single-source supply and no telemetry on the LMO tank. The nationwide PSA rollout added generation capacity fast, but also left a large installed base of plants never properly integrated with the downstream pipeline, alarm system or reserve manifold. Much MGPS work in India today is not greenfield — it is correcting that gap.

As a turnkey MGPS installation company, RayMedico Projects handles the whole chain — load assessment, design, plant selection, pipework, terminals, alarms, testing, certification and long-term maintenance — under one contract.

Gases Covered by a Hospital MGPS

A standard Indian multi-specialty hospital pipes six services. Each has a distinct source, pressure, purity requirement and failure consequence.

Oxygen (O2) at 400 kPa / 4 bar. The primary clinical gas and the one that drives most design decisions. Sourced from an LMO tank, an on-site PSA plant or an automatic cylinder manifold — ideally two of these plus a reserve. Purity is 99.5 percent from liquid oxygen and nominally 93 percent plus or minus 3 percent from PSA generation, the pharmacopoeial Oxygen 93 grade. It is the highest-consumption gas, has the widest peak-to-average swing, and is the only service where failure is immediately life-threatening.

Nitrous oxide (N2O) at 400 kPa / 4 bar. Anaesthetic gas for theatres, labour rooms and some dental and paediatric areas, almost always fed from an automatic changeover cylinder manifold since consumption is low and intermittent. N2O demands strict terminal non-interchangeability, its own colour coding, and pipework never cross-linked with oxygen.

Medical air at 400 kPa / 4 bar. Oil-free compressed air for ventilators, nebulisers, blenders and neonatal CPAP, from oil-free compressors with duplex desiccant dryers and multi-stage filtration, delivering a pressure dew point typically below minus 40 degrees C with controlled CO, CO2 and oil content. Contaminated medical air reaches neonatal lungs directly, so this is quality-critical.

Surgical air at 700 kPa / 7 bar. A separate, higher-pressure service driving pneumatic tools — orthopaedic drills, saws, dermatomes, tourniquets. Frequently confused with 4-bar medical air and wrongly omitted from budgets. Short-duration but very high flow, around 350 L/min per outlet with no diversity allowance, so it needs its own compressor and receiver rather than a regulator off the 4-bar main.

Medical vacuum. Suction for airway management, surgical fields and drainage, from a duplex or triplex plant with receiver, bacterial filtration and drainage trap. The pipeline must sustain a minimum of minus 400 mmHg at the terminal under full diversified load. Vacuum is the most frequently undersized service in Indian hospitals, because pressure loss on long horizontal runs is easy to underestimate.

AGSS — Anaesthetic Gas Scavenging System. Expels waste anaesthetic gas from the patient circuit to outside the building, protecting theatre staff from chronic exposure to volatile agents. It uses a dedicated disposal unit, receiving systems at each anaesthetic machine, and separate ducting — never the vacuum plant. A staff-safety requirement, and one of the first things an assessor checks.

Carbon dioxide (CO2) at 400 kPa / 4 bar. Laparoscopic insufflation and some cryotherapy and cardiac work, piped from a small manifold where volumes justify it. Nitrogen at 7 bar and Entonox appear only in specific facilities.

Medical Gas Pipeline Cost in India

Medical gas pipeline cost splits into three buckets: distribution (pipework, terminals, valves, alarms), plant room (generation and storage), and bedside interface (bed head panels and pendants). Budgeting only one bucket is the most common reason hospital MGPS costs go wrong mid-project.

Cost per gas outlet. ₹7,000 to ₹15,000 per terminal in ward and OPD areas; ₹12,000 to ₹22,000 in ICU, theatre and emergency zones. That is fully loaded — the terminal unit plus its proportionate share of copper, brackets, zone valve, alarm coverage and labour. A bare terminal costs a fraction of this; the pipework behind it does not.

Cost per bed. The number most hospital planners actually need:

Bed typeServicesIndicative cost per bed
General wardO2 + vacuum₹25,000 – ₹45,000
HDU / step-downO2, air, vacuum₹60,000 – ₹1.1 lakh
ICU (Level 3)5–6 services + BHP₹1.2 – ₹2.2 lakh
Operating theatreFull suite + AGSS₹3.5 – ₹7 lakh per OT

Theatre figures cover pipework, terminals and AGSS only; pendants and consoles are quoted separately, their price range being far wider than the pipeline behind them.

Indicative whole-hospital distribution cost — pipework, terminals, valves, manifolds and alarms, excluding PSA plant, LMO tank and pendants:

Hospital sizeTypical bed mixDistribution cost
50 beds8–10 ICU, 1–2 OT₹18 – ₹35 lakh
100 beds15–20 ICU, 3–4 OT₹35 – ₹70 lakh
200 beds35–45 ICU, 6–8 OT₹70 lakh – ₹1.4 crore

Plant room, costed separately. A PSA oxygen plant runs roughly ₹18 to ₹30 lakh at 20 Nm3/hr, ₹30 to ₹55 lakh at 40 Nm3/hr, and ₹70 lakh to ₹1.2 crore at 100 Nm3/hr, including compressor, dryer, buffer tanks and controls. A duplex oil-free medical air plant is ₹6 to ₹15 lakh, a vacuum plant ₹5 to ₹12 lakh, an automatic 2 x 10 cylinder oxygen manifold ₹1.5 to ₹3.5 lakh, and an LMO tank with vaporiser ₹25 to ₹60 lakh — though in India the tank is frequently leased from the industrial gas supplier. Bed head panels add ₹12,000 to ₹45,000 per bed.

What drives the price up. ICU-heavy and theatre-heavy bed mixes, where outlet density per bed doubles or triples. High-rise or multi-tower layouts with long risers. Imported BS or NIST terminal units. Full N+1 redundancy on every plant. Adding 7-bar surgical air and AGSS, which first-draft budgets routinely omit. Retrofit in a live hospital, where night working and phased tie-ins add 15 to 30 percent to labour. Third-party validation. And copper — tube is typically 40 to 60 percent of distribution material cost, so quotations track LME rates and are usually valid only 15 to 30 days.

What brings the price down. Engaging the MGPS designer at civil design stage so pipework runs in shafts rather than around obstructions. A compact single-tower footprint. A ward-weighted bed mix. Choosing a manifold plus reserve over a PSA plant below roughly 50 oxygen-dependent beds. Standardising on one terminal unit type hospital-wide. And procuring the full scope as one package instead of splitting pipework, plant and panels across three vendors who each price their own interface risk.

Treat every figure above as an indicative Indian-market planning range, not a quotation.

HTM 02-01 vs NFPA 99 vs ISO 7396-1: Which Standard Applies in India

India has no single mandatory MGPS engineering code, so in practice all three standards are used — but not equally.

HTM 02-01 is the working design bible for Indian MGPS. The UK Health Technical Memorandum is the most prescriptive of the three: design flow rates per terminal type, diversity factors by department, pipe sizing methodology, the full testing and commissioning regime, and the permit-to-work and Authorised Person governance framework. When an Indian tender says “HTM compliant,” this is what it means, and it is the standard we design to by default.

NFPA 99 is the US Health Care Facilities Code. Its contribution here is structural rather than dimensional: the three-source supply philosophy (primary, secondary, reserve), the risk-category approach grading systems by clinical consequence of failure, and a strong emphasis on qualification of installers, brazers and verifiers. Projects with US-affiliated stakeholders or JCI ambitions are usually asked for NFPA 99 alignment alongside HTM.

ISO 7396-1 is the international consensus standard — less prescriptive on flow numbers, more focused on safety architecture: terminal unit non-interchangeability, source system requirements, monitoring and alarms, and risk management. It matters because the component certification chain references it: terminal units to ISO 9170-1, hoses to ISO 5359, the system to ISO 7396-1.

NABH publishes no MGPS engineering code — it audits whether you designed to a recognised standard and can prove it. Domestically, the BIS family (IS 7396 series for cylinder colour identification, IS 7902 for installation practice) governs marking and workmanship, and PESO approvals apply to bulk oxygen storage.

Our default for an Indian hospital: size to HTM 02-01, adopt the NFPA 99 three-source rule, specify components certified to ISO 7396-1 and ISO 9170-1, and document in the format a NABH assessor expects.

Design and Sizing: Flow Rates, Diversity and Redundancy

Undersize the pipeline and you get pressure drop at the furthest outlet exactly when every bed is loaded. Oversize it and you have paid a premium in copper for capacity that never gets used.

Design flows. HTM 02-01 assigns a design flow to each terminal type rather than each bed: ward oxygen terminals at roughly 10 L/min, theatre oxygen suites around 100 L/min, medical air 20 to 80 L/min by clinical area, vacuum around 40 L/min free air per terminal against a minimum of minus 400 mmHg, and 7-bar surgical air roughly 350 L/min per outlet with no diversity applied.

Diversity factors. A hospital never draws peak simultaneously — but ICUs come far closer than wards. Diversity is applied by department: aggressive in general wards, minimal in ICU and neonatal units, effectively none for surgical air. The most common Indian sizing error is applying a ward diversity factor across an ICU floor — precisely the failure mode that surfaced during the 2021 oxygen surge. We size ICU oxygen with explicit surge headroom.

Pipeline sizing. Copper is sized on diversified flow against an allowable pressure drop from source to the most remote terminal, with velocity limits to prevent noise and erosion. Sizes run 12mm and 15mm at branch level up to 76mm and 108mm on risers and plant headers. Vacuum mains are sized more generously than intuition suggests, because vacuum degrades faster than pressure gas over distance.

Redundancy. Oxygen needs three independent sources — typically PSA as primary, LMO or a second bank as secondary, an emergency cylinder manifold as reserve, plus an emergency supply connection point outside the building. Air and vacuum plants are duplex or triplex so any unit can be serviced while the rest carry full diversified load, with automatic changeover annunciated on the master panel.

Manifold or PSA? Below roughly 50 oxygen-dependent beds, an automatic cylinder manifold with a good reserve is usually rational: low capital cost, no power dependency, minimal maintenance. Between 50 and 150 oxygen beds, PSA typically pays back in two to four years against cylinder purchase, given stable power and adequate plant room ventilation. Above 150 beds, or where surge loads are high, LMO as primary with PSA or manifold backup is more robust. Decide on a modelled load profile, not capital cost alone.

Installation, Brazing, Purging and Pressure Testing

MGPS quality is decided during installation, and most of it is invisible after the false ceiling goes up.

Copper tube arrives degreased and capped from the mill and stays capped until the moment of jointing. Runs are set out with correct bracket spacing, expansion allowance and separation from electrical services and heat sources. Every pipe is colour-coded and labelled with gas identity and flow direction at intervals, at every penetration and either side of every valve — so anyone opening a ceiling in five years knows what they are looking at.

Joints are silver brazed with a continuous internal purge of oxygen-free nitrogen. This is non-negotiable: brazing copper without an inert purge forms black cupric oxide scale on the bore that later breaks loose and travels downstream into regulators, ventilators and patient circuits. Brazers should be individually qualified and their joints traceable. Copper-to-copper joints use copper-phosphorus filler with no flux; dissimilar-metal joints use silver filler with controlled flux.

The completed network is purged with dry nitrogen or oil-free air to sweep out particulates, then pressure tested at 1.5 times working pressure, held and logged with temperature compensation. Zone valves are tested for isolation integrity — each AVSU must actually isolate the zone it is labelled for, verified by physical test rather than by drawing. Only once the distribution network is proven is it connected to the source plant.

Anti-confusion testing matters most: every outlet in the hospital is tested with gas-specific equipment to confirm it delivers only its intended gas, at the correct pressure, through a mechanically non-interchangeable probe. There is no acceptable sampling rate. One hundred percent, every time.

Testing, Validation and Certification

The distinction between a functioning pipeline and a certified one is documentation. A hospital that cannot produce test records has, from an accreditation standpoint, an untested system.

Our commissioning sequence covers pressure and leak testing with recorded hold data, cross-connection and anti-confusion testing on every terminal, mechanical function and interchangeability checks, zone valve isolation verification, particulate testing, purge and quality-of-gas testing (purity, dew point, carbon monoxide, carbon dioxide, oil content and odour, sampled at the most remote outlets), alarm function testing on every area and master panel including simulated faults, plant changeover and reserve activation, and final flow and pressure verification at diversified load.

At handover the hospital receives a bound and digital validation dossier: as-built drawings with valve and zone schedules, design calculations with stated flow and diversity assumptions, material and copper mill test certificates, signed stage-by-stage test records, gas quality certificates, alarm and gauge calibration records, a valve identification schedule for nursing stations, the preventive maintenance schedule, emergency shutdown procedures, and staff training records.

That dossier is structured the way a NABH assessor works through the section, so it goes into the audit file directly. Hospitals lose points here far more often for missing records than for defective hardware.

AMC and Maintenance

An MGPS degrades quietly. Filters load up, desiccant beds saturate, PSA sieve performance drifts, alarm sensors lose calibration, valve seats stiffen, probe seals harden. None of it announces itself until a purity test fails or a ventilator alarms.

Our annual maintenance contracts cover quarterly plant room preventive maintenance, compressor and vacuum pump servicing to manufacturer schedules, filter and desiccant replacement, PSA sieve health assessment with oxygen purity verification, annual calibration of alarm panels, sensors and gauges, zone valve exercising, rolling terminal probe and seal testing, leak surveys on distribution mains, and annual re-validation with fresh gas quality certificates. Every visit produces a report in NABH-ready format, so the maintenance file builds itself.

We also provide the operational scaffolding hospitals often lack: a permit-to-work procedure for interventions on live pipework, refresher training for nursing and biomedical staff on zone valve locations and emergency shutdown, and support during accreditation assessments. AMC is typically 6 to 10 percent of MGPS capital value per year, depending on plant inventory and spares cover.

Why RayMedico Projects for MGPS

Single accountable partner. Most Indian hospitals end up with a pipeline contractor, a PSA vendor, a panel supplier and a testing agency — four parties, four warranties, four explanations when something fails at the interface. We take the whole scope: load assessment, design, plant, pipework, terminals, alarms, testing, certification and AMC. One contract, one project manager.

Compliance built in, not bolted on. We design to HTM 02-01, adopt the NFPA 99 three-source rule, and specify to ISO 7396-1 and ISO 9170-1 from the first drawing, because retrofitting compliance onto an installed pipeline costs several times what designing it in costs. The validation dossier is structured for NABH audit from the outset.

Quality materials, verified. Degreased seamless copper to EN 13348 with mill test certificates, gas-specific non-interchangeable terminals, oil-free air plants with verified dew point performance, and nitrogen-purged brazing by qualified brazers. In medical gas work, materials and workmanship are the specification.

Coordinated with the rest of the build. MGPS touches modular theatres, ICU bed head panels, cath labs and HVAC shafts. Because we deliver those services too, gas routing is coordinated with theatre panels, pendant positions and ceiling services at design stage rather than negotiated on site with a hole saw.

Long-term partnership. Through the RayMedico ecosystem, hospitals equip departments via RayMedico Marketplace and maintain the installation under our AMC programme. We care what the system does in year eight, not how it looks at handover.

Whether you are planning a new hospital, expanding a critical care block, or correcting a PSA plant installed fast in 2021 and never properly integrated, we start with a site survey and load assessment. Contact us for a detailed MGPS proposal.

Components & Features

What's Included

Every component engineered to work as a unified system.

🫁

Oxygen Distribution

Centralised O2 supply from LMO tank, PSA plant or manifold — with zone valves, line regulators, and full alarm coverage.

💨

Medical Air & Vacuum

Oil-free 4-bar medical air and 7-bar surgical air plants, plus duplex vacuum plants with N+1 redundancy for critical care.

⚗️

Nitrous Oxide & CO2

Anaesthetic gas and CO2 distribution with automatic changeover manifolds, non-return valves, and safety interlocks.

🛡️

AGSS

Anaesthetic Gas Scavenging Systems for theatre and recovery areas, protecting staff from chronic waste-gas exposure.

🏭

PSA Oxygen Plants & Manifolds

On-site PSA oxygen generation sized in Nm3/hr, integrated with LMO backup and cylinder manifold reserve for three-source supply.

🚨

Alarms, Valves & Terminal Units

Master and area alarm panels, AVSU zone isolation, and gas-specific non-interchangeable terminal units at every bedside.

Built to These Standards

Our Process

Our Process

A proven five-phase approach for every project.

01

Site Survey & Load Assessment

Department-by-department gas demand mapping, peak and diversified flow calculation, plant room siting, and 10-year growth headroom.

02

Design & Engineering

Pipeline routing and sizing, terminal unit schedules, manifold and plant sizing, alarm zoning, and NABH-aligned drawing sets for approval.

03

Premium Material Procurement

Degreased medical-grade copper to EN 13348, ISO 9170-1 terminal units, ISO 5359 hoses, and certified manifolds with mill test certificates.

04

Installation & Brazing

Nitrogen-purged silver brazing by qualified brazers, colour-coded and labelled runs, bracketed supports, and first-fix coordination with civil and HVAC.

05

Testing & Commissioning

Pressure and leak testing, cross-connection checks, particulate and purity verification, alarm function tests, and a full validation dossier at handover.

Full Specification

Complete Component List

Medical-grade seamless copper pipeline to EN 13348 (degreased, capped, 12mm to 108mm)
Automatic changeover manifold systems (O2, N2O, CO2, N2)
Emergency and reserve cylinder manifold banks
PSA oxygen generation plant with air receiver, dryer, and oxygen buffer tank
Liquid medical oxygen (LMO) tank, vaporiser, and telemetry interface
Oil-free medical air plant at 4 bar with duplex dryers and triple filtration
Surgical air plant at 7 bar for pneumatic tools and tourniquets
Medical vacuum plant with receiver, bacterial filters, and drainage trap
AGSS disposal units, receiving systems, and theatre scavenging terminals
Area Valve Service Units (AVSU) and zone isolation valve boxes
Line pressure regulators, non-return valves, and filter assemblies
Area alarm panels with audio-visual annunciation per department
Master alarm panel and plant status monitoring with BMS output
Terminal units / gas outlets — gas-specific, non-interchangeable (BS, DISS, NIST or Ohmeda)
Bed head panels — horizontal and vertical, with services, sockets, and nurse call integration
Ceiling pendants, surgical consoles, and ICU bridges
FAQ

Frequently Asked Questions

Common questions about medical gas pipeline system.

What is a medical gas pipeline system?

A medical gas pipeline system (MGPS) is a centralised network that distributes medical gases — oxygen, nitrous oxide, medical air, surgical air, vacuum and CO2 — from a bulk source to terminal units at the bedside, in operating theatres, ICUs, labour rooms, and emergency departments. It replaces trolley-mounted cylinders with a continuous, monitored, pressure-regulated supply. A complete MGPS includes the source plant, distribution pipework, zone isolation valves, pressure regulation, alarm systems, and gas-specific terminal units. Because a fault anywhere in the chain reaches a ventilated patient within seconds, MGPS is treated as a critical life-support installation, not a plumbing service.

What is the cost of medical gas pipeline per bed in India?

Medical gas pipeline cost per bed in India typically runs ₹25,000 to ₹45,000 for a general ward bed with two outlets, ₹60,000 to ₹1.1 lakh for an HDU or step-down bed, and ₹1.2 lakh to ₹2.2 lakh for a full ICU bed with five to six services plus a bed head panel. On a per-outlet basis, expect ₹7,000 to ₹15,000 per terminal unit in ward areas and ₹12,000 to ₹22,000 in ICU and theatre zones, inclusive of proportionate pipework, valves, and alarms. Plant room equipment — PSA, LMO, air and vacuum plants — is costed separately. Exact figures follow a site survey.

What standards apply to MGPS in India?

There is no single mandatory Indian MGPS code, so Indian hospitals design to HTM 02-01 as the primary reference, cross-checked against NFPA 99 and ISO 7396-1. HTM 02-01 governs design flows, diversity factors, pipe sizing, testing regimes and the permit-to-work system. NFPA 99 contributes the three-source supply rule and installer qualification discipline. ISO 7396-1 anchors terminal unit non-interchangeability and system safety requirements. BIS standards including the IS 7396 series and IS 7902 cover cylinder colour identification and Indian installation practice. NABH does not publish its own engineering code — it audits whether you designed to a recognised standard and can prove it with documentation.

Which gases are included in a hospital medical gas pipeline system?

A standard Indian multi-specialty hospital pipes six services. Oxygen at 4 bar is the primary clinical gas. Nitrous oxide at 4 bar serves theatres and labour rooms. Medical air at 4 bar drives ventilators and nebulisers. Surgical air at 7 bar powers orthopaedic drills, saws and tourniquets. Medical vacuum provides suction at a minimum of minus 400 mmHg. AGSS removes waste anaesthetic gas from theatres and recovery. CO2 at 4 bar is added where laparoscopy volumes justify a pipeline instead of cylinders. Nitrogen at 7 bar and Entonox appear only in specific facilities such as high-end orthopaedic centres and maternity units.

How long does medical gas pipeline installation take?

For a 100-bed hospital built from scratch, MGPS design through commissioning typically runs 60 to 90 working days, sequenced around the civil programme. Design and drawing approval takes 10 to 15 days, material procurement 15 to 25 days, first-fix pipework 25 to 40 days spread across floors, second-fix terminals and panels 10 to 15 days, and testing, purging and validation another 10 to 15 days. Plant room installation runs in parallel. Retrofit work in a live hospital takes longer in calendar terms because it is executed ward-by-ward in shutdown windows, often on night shifts, to avoid interrupting clinical services.

PSA oxygen plant or liquid oxygen tank — which should a hospital choose?

It depends on bed count, load profile, and space. A PSA plant generates Oxygen 93 on site at roughly 93 percent purity plus or minus 3 percent, needs no logistics chain, and typically makes sense above 50 to 60 oxygen-dependent beds where power supply is stable. Payback against cylinder purchase is commonly quoted at two to four years. An LMO tank supplies 99.5 percent purity, handles very high peak loads comfortably, and suits 150-plus bed hospitals with reliable tanker access, but it requires a statutory-approved site, PESO clearance, and a vendor contract. Most well-designed Indian hospitals use both, with a cylinder manifold as the third reserve source.

What copper pipe is used for medical gas pipelines?

Medical gas pipelines use seamless phosphorus-deoxidised copper tube manufactured to EN 13348, supplied degreased, internally cleaned, and capped at both ends at the mill. Ordinary plumbing or refrigeration copper is not acceptable — residual drawing oils in a 4-bar oxygen line are a fire risk and a patient contamination risk. Tube is usually half-hard R250 for straight runs and annealed R220 where forming is needed. Common sizes run 12mm through 108mm outside diameter, sized against diversified flow. Every consignment should arrive with mill test certificates and remain capped on site until the moment of brazing.

What testing and certification is required before MGPS commissioning?

A compliant handover requires a documented sequence, not a single pressure check. It includes an initial pressure and leak test at 1.5 times working pressure held and logged, a cross-connection test proving each outlet delivers only its intended gas, mechanical function and interchangeability checks on every terminal unit, zone valve isolation verification, particulate testing at outlets, purge and quality-of-gas testing covering purity, dew point, carbon monoxide, carbon dioxide, oil content and odour, alarm function testing for every area and master panel, and a final anti-confusion test. Each stage is signed off before the system is released for clinical use.

What does NABH require for medical gas systems?

NABH assessors look for evidence rather than equipment. They expect as-built MGPS drawings with valve and zone identification, design calculations showing flow and diversity assumptions, material and component certificates, the full commissioning and validation test dossier, gas purity certificates, calibration records for alarm panels and pressure gauges, a documented preventive maintenance schedule with completed logs, a permit-to-work procedure for any pipeline intervention, emergency procedures for gas failure, and records of staff training on shut-off valve locations. Hospitals fail this section far more often on missing paperwork than on defective hardware, which is why we hand over an audit-ready dossier.

How many gas outlets does an ICU bed need?

A typical Indian Level-3 ICU bed is provisioned with two oxygen outlets, one 4-bar medical air outlet, and two vacuum outlets, giving five services per bed, with a sixth outlet added where the unit runs high-frequency ventilation or ECMO. HDU and step-down beds usually take one oxygen, one air and one vacuum. General ward beds take one oxygen and one vacuum. Operating theatres are provisioned per theatre rather than per bed: two oxygen, two nitrous oxide, two 4-bar air, one 7-bar surgical air, three vacuum, one CO2 and two AGSS terminals is a common major-theatre schedule.

Do you provide AMC for medical gas pipeline systems?

Yes. Our comprehensive AMC covers quarterly preventive maintenance of the plant room, oil-free compressor and vacuum pump servicing, filter and desiccant replacement, PSA sieve health checks with oxygen purity verification, annual alarm and sensor calibration, zone valve exercising, terminal unit probe and seal testing, leak surveys on distribution mains, and annual re-validation with fresh gas quality certificates. Documentation is issued in NABH-ready format after every visit. AMC is typically priced at 6 to 10 percent of the MGPS capital value per year depending on plant inventory and whether spares are included.

Can MGPS be installed in a running hospital?

Yes, and most Indian expansion projects are exactly this. The method is to build the new pipework as an isolated section, test and certify it fully while it is still disconnected, then tie it into the live system during a short, planned shutdown under a formal permit-to-work with a nominated Authorised Person from the hospital. Tie-ins are scheduled at low-occupancy hours, cylinder backup is staged at affected bedsides beforehand, and the affected zone is re-tested and re-certified before patients return. Sequencing and communication with nursing leadership matter more than the pipefitting itself.
Where We Build

Medical Gas Pipeline System across India

City-specific guidance on cost, logistics, and local compliance for medical gas pipeline system projects.